Volume 25 Issue 4
Aug.  2012
Turn off MathJax
Article Contents

YIN Ji Yong, SUN Jing, HUANG Jian, LI Wen Xian, HUO Jun Sheng. Study on The Method of Quantitative Analysis of Serum Ferritin and Soluble Transferrin Receptor with Protein Microarray Technology[J]. Biomedical and Environmental Sciences, 2012, 25(4): 430-439. doi: 10.3967/0895-3988.2012.04.008
Citation: YIN Ji Yong, SUN Jing, HUANG Jian, LI Wen Xian, HUO Jun Sheng. Study on The Method of Quantitative Analysis of Serum Ferritin and Soluble Transferrin Receptor with Protein Microarray Technology[J]. Biomedical and Environmental Sciences, 2012, 25(4): 430-439. doi: 10.3967/0895-3988.2012.04.008

Study on The Method of Quantitative Analysis of Serum Ferritin and Soluble Transferrin Receptor with Protein Microarray Technology

doi: 10.3967/0895-3988.2012.04.008
Funds:  The 863 Program entitled as “The research and exploration of nutrition fortified food for improving growth and development(2010AA023004)%The Trace Elements Nutrition Key Laboratory of the Ministry of Health
  • Objective To establish and evaluate a protein microarray method for combined measurement of serum ferritin (SF) and soluble transferrin receptor (sTfR).Methods Microarrayer was used to print both anti-SF antibodies Ⅰ and anti-sTfR antibodies I on each protein microarray.Anti-SF antibodies Ⅱ and anti-sTfR antibodies Ⅱ were used as detection antibodies and goat antibodies coupled to Cy3 were used as antibodies Ⅲ.The detection conditions of the quantitative analysis method for simultaneous measurement of SF and sTfR with protein microarray were optimized and evaluated.The protein microarray was compared with commercially available traditional tests with 26 serum samples.Results By comparison experiment,mouse monoclonal antibodies were chosen as the probes and contact printing was chosen as the printing method.The concentrations of SF and sTfR probes were 0.5mg/mL and 0.5 mg/mL respectively,while those of SF and sTfR detection antibodies were 5 μg/mL and 0.36 μg/mL respectively.Intra- and inter-assay variability was between 3.26% and 18.38% for all tests.The regression coefficients comparing protein microarray with traditional test assays were better than 0.81 for SF and sTfR.Conclusion The present study has established a protein microarray method for combined measurement of SF and sTfR.
  • 加载中
  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article Metrics

Article views(1008) PDF downloads(42) Cited by()

Proportional views
Related

Study on The Method of Quantitative Analysis of Serum Ferritin and Soluble Transferrin Receptor with Protein Microarray Technology

doi: 10.3967/0895-3988.2012.04.008
Funds:  The 863 Program entitled as “The research and exploration of nutrition fortified food for improving growth and development(2010AA023004)%The Trace Elements Nutrition Key Laboratory of the Ministry of Health

Abstract: Objective To establish and evaluate a protein microarray method for combined measurement of serum ferritin (SF) and soluble transferrin receptor (sTfR).Methods Microarrayer was used to print both anti-SF antibodies Ⅰ and anti-sTfR antibodies I on each protein microarray.Anti-SF antibodies Ⅱ and anti-sTfR antibodies Ⅱ were used as detection antibodies and goat antibodies coupled to Cy3 were used as antibodies Ⅲ.The detection conditions of the quantitative analysis method for simultaneous measurement of SF and sTfR with protein microarray were optimized and evaluated.The protein microarray was compared with commercially available traditional tests with 26 serum samples.Results By comparison experiment,mouse monoclonal antibodies were chosen as the probes and contact printing was chosen as the printing method.The concentrations of SF and sTfR probes were 0.5mg/mL and 0.5 mg/mL respectively,while those of SF and sTfR detection antibodies were 5 μg/mL and 0.36 μg/mL respectively.Intra- and inter-assay variability was between 3.26% and 18.38% for all tests.The regression coefficients comparing protein microarray with traditional test assays were better than 0.81 for SF and sTfR.Conclusion The present study has established a protein microarray method for combined measurement of SF and sTfR.

YIN Ji Yong, SUN Jing, HUANG Jian, LI Wen Xian, HUO Jun Sheng. Study on The Method of Quantitative Analysis of Serum Ferritin and Soluble Transferrin Receptor with Protein Microarray Technology[J]. Biomedical and Environmental Sciences, 2012, 25(4): 430-439. doi: 10.3967/0895-3988.2012.04.008
Citation: YIN Ji Yong, SUN Jing, HUANG Jian, LI Wen Xian, HUO Jun Sheng. Study on The Method of Quantitative Analysis of Serum Ferritin and Soluble Transferrin Receptor with Protein Microarray Technology[J]. Biomedical and Environmental Sciences, 2012, 25(4): 430-439. doi: 10.3967/0895-3988.2012.04.008

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return