Study on The Method of Quantitative Analysis of Serum Ferritin and Soluble Transferrin Receptor with Protein Microarray Technology

YIN Ji Yong SUN Jing HUANG Jian LI Wen Xian HUO Jun Sheng

YIN Ji Yong, SUN Jing, HUANG Jian, LI Wen Xian, HUO Jun Sheng. Study on The Method of Quantitative Analysis of Serum Ferritin and Soluble Transferrin Receptor with Protein Microarray Technology[J]. Biomedical and Environmental Sciences, 2012, 25(4): 430-439. doi: 10.3967/0895-3988.2012.04.008
Citation: YIN Ji Yong, SUN Jing, HUANG Jian, LI Wen Xian, HUO Jun Sheng. Study on The Method of Quantitative Analysis of Serum Ferritin and Soluble Transferrin Receptor with Protein Microarray Technology[J]. Biomedical and Environmental Sciences, 2012, 25(4): 430-439. doi: 10.3967/0895-3988.2012.04.008

doi: 10.3967/0895-3988.2012.04.008
基金项目: The 863 Program entitled as “The research and exploration of nutrition fortified food for improving growth and development(2010AA023004)%The Trace Elements Nutrition Key Laboratory of the Ministry of Health

Study on The Method of Quantitative Analysis of Serum Ferritin and Soluble Transferrin Receptor with Protein Microarray Technology

Funds: The 863 Program entitled as “The research and exploration of nutrition fortified food for improving growth and development(2010AA023004)%The Trace Elements Nutrition Key Laboratory of the Ministry of Health
计量
  • 文章访问数:  1019
  • HTML全文浏览量:  214
  • PDF下载量:  43
  • 被引次数: 0
出版历程
  • 刊出日期:  2012-08-20

Study on The Method of Quantitative Analysis of Serum Ferritin and Soluble Transferrin Receptor with Protein Microarray Technology

doi: 10.3967/0895-3988.2012.04.008
    基金项目:  The 863 Program entitled as “The research and exploration of nutrition fortified food for improving growth and development(2010AA023004)%The Trace Elements Nutrition Key Laboratory of the Ministry of Health

摘要: Objective To establish and evaluate a protein microarray method for combined measurement of serum ferritin (SF) and soluble transferrin receptor (sTfR).Methods Microarrayer was used to print both anti-SF antibodies Ⅰ and anti-sTfR antibodies I on each protein microarray.Anti-SF antibodies Ⅱ and anti-sTfR antibodies Ⅱ were used as detection antibodies and goat antibodies coupled to Cy3 were used as antibodies Ⅲ.The detection conditions of the quantitative analysis method for simultaneous measurement of SF and sTfR with protein microarray were optimized and evaluated.The protein microarray was compared with commercially available traditional tests with 26 serum samples.Results By comparison experiment,mouse monoclonal antibodies were chosen as the probes and contact printing was chosen as the printing method.The concentrations of SF and sTfR probes were 0.5mg/mL and 0.5 mg/mL respectively,while those of SF and sTfR detection antibodies were 5 μg/mL and 0.36 μg/mL respectively.Intra- and inter-assay variability was between 3.26% and 18.38% for all tests.The regression coefficients comparing protein microarray with traditional test assays were better than 0.81 for SF and sTfR.Conclusion The present study has established a protein microarray method for combined measurement of SF and sTfR.

English Abstract

YIN Ji Yong, SUN Jing, HUANG Jian, LI Wen Xian, HUO Jun Sheng. Study on The Method of Quantitative Analysis of Serum Ferritin and Soluble Transferrin Receptor with Protein Microarray Technology[J]. Biomedical and Environmental Sciences, 2012, 25(4): 430-439. doi: 10.3967/0895-3988.2012.04.008
Citation: YIN Ji Yong, SUN Jing, HUANG Jian, LI Wen Xian, HUO Jun Sheng. Study on The Method of Quantitative Analysis of Serum Ferritin and Soluble Transferrin Receptor with Protein Microarray Technology[J]. Biomedical and Environmental Sciences, 2012, 25(4): 430-439. doi: 10.3967/0895-3988.2012.04.008

目录

    /

    返回文章
    返回